Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | S-480-0-5 | S-480-0-12 | S-480-0-24 | S-480-0-36 | S-480-0-48 | S-480-0-60 |
DC Output voltage | 5V | 12V | 24V | 36V | 48V | 60V |
Output voltage range DC | 0-5V | 0-12V | 0-24V | 0-36V | 0-48V | 0-60V |
Rated output current | 60A | 40A | 20A | 15A | 10A | 8A |
Wave and noise | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p |
Inlet stability | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 80% | 83% | 83% | 84% | 86% | 87% |
Model | S-480-0-80 | S-480-0-120 | S-480-0-160 | S-480-0-220 | S-480-0-300 | |
DC Output voltage | 80V | 120V | 160V | 220V | 300V | |
Output voltage range DC | 0-80V | 0-120V | 0-160V | 0-220V | 0-300V | |
Rated output current | 6A | 4A | 3A | 2A | 1.6A | |
Wave and noise | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | |
Inlet stability | ±1% | ±1% | ±1% | ±1% | ±1% | |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Efficiency | 87% | 88% | 88% | 89% | 89% |
AC input voltage range | 100-132VAC/190-240VAC selected by switch 47-63Hz | |||||
Input current | 5A/230V | |||||
Setup rise hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | Input and output intemal:1.5KVAC,input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||
lsolation resistance | Input and output interal:lnput and enclosure,Output and encosure:500VDC/100MΩ | |||||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||||
Protection | Over-voltage, over-load, over-current, over-temperature | |||||
Overall dimension | 215*115*50mm(L*W*H) | |||||
Weight | 0.9kgs | |||||
Safety standards | GB4949,UL60950,EN60950 | |||||
EMC standards | According to GB9254 EN55022 EN55024 A level design | |||||
Note: | ||||||
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. | ||||||
2.Error.include the setting error,line stability and load stability.(Note:5). | ||||||
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||||
5.Load stability test:the load is from 0% to 100%. | ||||||
6.C2,3,6must be knocked down. |