XLG-1500 | |||||
Model | XLG-1500-24 | XLG-1500-36 | XLG-1500-48 | XLG-1500-110 | |
Output | DC output voltage | 24V | 36V | 48V | 110V |
Rated output current | 55A | 41.5A | 31A | 13.6A | |
Current range | 0-55A | 0~41.5A | 0~31A | 0~13.6A | |
Output power | 1320W | 1494W | 1488W | 1496W | |
Ripple and noise | 240mVp-p | 300mVp-p | 350mVp-p | 650mVp-p | |
Voltage accuracy. Remarks 3 | ±2% | ±2% | ±2% | ±2% | |
Line regulation. Remarks 4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulation. Remarks 5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Start Rise Hold Times | 500ms,50ms,24ms/230VAC(at full load) | ||||
Input voltage range | 180~264VAC,245~373VDC | ||||
Input | Frequency range | 47~63Hz | |||
AC input current | 13.5A/230VAC | ||||
Power factor | 0.5~0.7 | ||||
Efficiency | 93.50% | 94.50% | 95% | 95% | |
Impact current | Cold-start current 65A/230VAC | ||||
Leakage current | <2mA/240VAC |
Protection features | Overload protection | 95%~105% of the rated output current triggers overcurrent limitation, which can be automatically restored after abnormal conditions are removed | |||
Short circuit protection | Protection method: Current limiting mode, automatically restores normal output after abnormal conditions are removed | ||||
Overvoltage protection | Starting overvoltage protection at 115%~135% of rated output voltage | ||||
Protection method: Voltage limiting mode, which can automatically restore normal output after removing abnormal conditions | |||||
Over temperature protection | 105℃± 5℃(temperature around the transformer, current limiting mode protection after overheating, automatic recovery after cooling) | ||||
Protection method: Reduce the output voltage, reduce the output current, and automatically restore normal output after the temperature drops | |||||
Environment | Working temperature | -40℃~+70℃ | |||
Working humidity | 20%~90%RH,non-condensing | ||||
Storage temperature and humidity | -40℃~+85℃;10%~95%RH,non-condensing | ||||
Shock resistance | 10~500Hz,5G 12min./1cycle,72min | ||||
Safety | Voltage resistance | Input/output (I/P~O/P): 1.5KVAC input to ground (V/P~FG): 1.5KVAC output to ground (O/P~FG): 0.5KVAC | |||
Insulation resistance | Input/output (I/P-O/P), input to ground (I/P-FG), output to ground (O/P-FG): 100M Ohms/500VDC/25℃/70% RH | ||||
Compliant with standards | Safety standards | Compliant with UL60950-1 and TUV EN60950-1 | |||
EMC emission | Compliant with EN55022 Class A | ||||
EMC immunity | Compliant with EN55024 | ||||
Other | Dimension | 320*120*56mm(L*W*H) | |||
Weight | 2.75kg |
Note | 1. All parameters are measured values obtained under the conditions of 230VAC voltage input, rated load and 25℃unless otherwise specified. | ||||
2. Ripple and noise voltage were measured on a 20MHz bandwidth oscilloscope with 0.1 μ and 47 μ capacitors added to the end of a 12 inch twisted pair cable. | |||||
3. Accuracy: Voltage setting error, linear adjustment rate, and load adjustment rate. | |||||
4. Linear adjustment rate measurement method: Test from low voltage to high voltage under rated load. | |||||
5. Measurement method for load adjustment rate: from 0% to 100% rated load. | |||||
6. The power supply should be considered as a part of the system components and electromagnetic compatibility related confirmation should be carried out in conjunction with the terminal equipment. |