Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SC-60-12 | SC-60-24 | |||
Output | DC voltage | CH1:13.8v | CH2:13.4V | CH1:27.6v | CH2:26.5V |
voltage tolerance | 1% | ±1% | |||
Rated current | 4.0A | 0.5A | 2.0A | 0.25A | |
current range | 0~4A | 0~2A | |||
Rated power | 59.9w | 61.8w | |||
Ripple&noise | 100mvp-p | 100mvp-p | |||
DC voltage ADJ. range | CH1:11.3~14.9v | CH1:21.3~29.8v | |||
Input | voltage range | 90~264VAC,127~370VDc | |||
frequency | 47~63HZ | ||||
AC current | 1.6A115VAC,0.8A230VAC | ||||
efficiency | 81% | 83% | |||
lnrush current | cold start current 25A115VAC,45A230VAc | ||||
Leakage current | <1mA240VAC | ||||
Protection | over load | Rated output power110%~150%start over load protection | |||
protection mode:AC charging mode:hiccup mode auto-recovery after fault condition is removed | |||||
Battery protection At low voltage | 9.5~11V 2o~22V | ||||
protection mode.cut off output |
Function | UPS introduction | long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop charging | |||
when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard, | |||||
cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs | |||||
Environment | Working temp,humidity | -10°C~+60°C,20%~90%RH | |||
Storagetemp,humidity | 20°C~+85°℃,10%~95%RH non-condensing | ||||
withstand vibration | 1o~500Hz,2G 10min/1cycle,period for 6o minutes,each axes | ||||
Safety | withstand voltage | /P-O/P:3KVAC WPFG:1.5KVAC O/PFG:0.5KVAC | |||
lsolated resistance | lP-O/P,I/PFG,O/P.FG:10OM ohms/500VDc | ||||
Fit standard | safety standard | compliance to UL60950-1 | |||
Others | Dimension | 129*98*38mm (L*W*H) | |||
Weight | 0.4kg |