Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency








MODEL | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 48V |
RATED CURRENT | 7.1A | 6.13A | 3.83A | 1.92A | |
CURRENT RANGE | 0~7.1A | 0~6.13A | 0~3.83A | 0~1.92A | |
RATED POWER | 85.2W | 92W | 92W | 92.2W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 12~13V | 15~17V | 24~25.5V | 48~48.7V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 500ms, 60ms/230VAC 500ms,60ms/115VAC at full load | ||||
HOLD UP TIME(Typ.) | 30ms/230VAC 12ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85~264VAC(277VAC operational) 120~370VDC (390VDC operational ) | |||
FREQUENCY RANGE | 47~63Hz | ||||
EFFICIENCY (Typ.) | 88% | 89% | 90% | 90% | |
AC CURRENT (Typ.) | 3A/115VAC 1.6A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | ||||
PROTECTION | OVERLOAD | 102~110% rated output power | |||
Hiccup mode when output voltage <50%,recovers automatically after fault condition is removed Constant current limiting within 50%~100% rated output voltage,recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 14.2~16.2V | 18.8~22.5V | 30~36V | 56.5~64.8V | |