Model | LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | |
Output | DC voltage | 5V | 12V | 15V | 24V | 36V |
Rated current | 14A | 6A | 5A | 3.2A | 2.1A | |
Current range | 0~14A | 0~6A | 0~5A | 0~3.2A | 0~2.1A | |
Rated power | 70W | 72W | 75W | 76.8W | 75.6W | |
Ripple noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
DC voltage ADJ. range | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage tolerance | ±3% | ±2% | ±1% | ±1% | ±1% | |
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load regulation | ±2% | ±1% | ±0.5% | ±0.5% | ±0.5% | |
Setup,rise,hold up time | 800ms,30ms,30ms/230VAC(full load) | |||||
Input | Voltage range | 90~264VAC,127~373VDC | ||||
Frequency range | 47~63HZ | |||||
AC current | 1.4A/115VAC 0.85A/230VAC | |||||
Inrush current | Cold start 45A/230VAC | |||||
Efficiency | 86% | 88% | 89% | 90% | 91% | |
Leakage current | <0.75mA/240VAC | |||||
Protection | overload | Rated output power110%~150% start over load protection | ||||
protection type: hiccup mode, auto-recovery after fault condition is removed | ||||||
Over voltage | Rated output voltage 115%~135% Start over voltage protection | |||||
Protection type: hiccup mode, auto-recovery after fault condition is removed | ||||||
Environment | Working temp,humidity | -30℃~+70℃(Please refer moderating curve”) | ||||
20%~90%RH Non-condensing | ||||||
Storage temp,humidity | -40℃~+85℃,10%~95%RH non-condensing | |||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | |||||
Safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | |||||
Fit standard | Safety standards | Compliance to UL60950-1,TUV EN60950-1,GB4943 | ||||
EMC emission | Compliance to EN55022(CISPR22)Class B,GB9254 Class B,EN55014,EN61000-3-2,3 | |||||
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 | |||||
Others | Dimension | 99*97*30mm(L*W*H) | ||||
Weight/packing | 0.25kg/45pcs/12.3kg/0.023m³/0.82CUFT | |||||
MTBF | ≥660K hrs min. MIL-HDBK-217F(25℃) | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||
4.Line regulation is measured from low line to high line at rated load. | ||||||
6.The ambient temperature derating of 5℃/1000 m is needed for operating altitude greater than 2000m(6500ft) | ||||||
7.The power supply is considered as a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives. | ||||||