4000W | ||||
Model | RSP-4000-24 | RSP-4000-36 | RSP-4000-48 | RSP-4000-60 |
DC Output Voltage | 24V | 36V | 48V | 60V |
Rated Output Current | 166.6A | 111A | 83.3A | 66.6A |
Rated Output Power | 3998W | 3996W | 3998W | 3996W |
Efficiency (at full load) | 89% | 91% | 91% | 92% |
Voltage regulation range | 17-25V | 25-36.5V | 33-48.5V | 41-60.5V |
Tip: When the output voltage is lowered, the maximum output current remains unchanged, but the output power decreases (power=voltage * current) | ||||
Equipped with active PFC power factor correction function | ||||
Input voltage | AC 230V±10%, 47-63HZ | |||
AC Input current | AC220V /40A(full load) | |||
Power factor (PF value) | PF value ≥ 0.98/110VAC (at 100% full load) | |||
Input Undervoltage Protection | When the AC input voltage is lower than 196V±1%, the power supply will not start. | |||
Fan shutdown protection | Either one of the two cooling fans is not running or the fan is not detected, the power supply has no output voltage, and it does not turn on | |||
over load protection | The overload protection mode is constant current limiting mode, which locks the output current value and prevents it from increasing. The output voltage decreases as the load increases | |||
Overheat protection | When the internal temperature of the power supply is too high, the overheat protection is activated, the output voltage is turned off, and after the temperature drops, it automatically recovers | |||
Short Circuit Protection | Short term instantaneous short circuit: shutdown, automatically restored after 3 seconds | |||
Long term continuous short circuit: Shut down, automatically restart once every 3 seconds (hiccup mode) | ||||
Output overvoltage protection | The overvoltage point is 130% of the nominal voltage value. After overvoltage, the protection is locked and will not automatically recover. It needs to be powered off and restored by re powering on | |||
Heat dissipation method | Temperature controlled automatic speed regulating fan (internal blowing mode, 2 fans) |