Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | PSC-250-12 | PSC-250-24 | |||
Output | DC Output Voltage | CH1:13.8V | CH2:13.8V | CH1:27.6V | CH2:27.6V |
Output Voltage Tolerance | ±1% | ±1% | |||
Rated output current | 14.5A | 3.5A(charge) | 6.5A | 2.5A(charge) | |
Output Current Range | 0~18A | ----- | 0~9A | ----- | |
output power | 250W | 250W | |||
Ripple and Noise | 180mVp-p | ----- | 200mVp-p | ----- | |
DC voltage adjustable range | CH1:11.3~14.9V | CH1:21.3~29.8V | |||
Start-up, rise and hold times | 600ms,50ms,80ms/230VAC.1200ms,50ms,16ms/115VAC. | ||||
Input | Input Voltage Range | 90~264VACor135~370VDC | |||
AC Input Current | 4.5A/115VAC 2.5A/230VAC | ||||
Efficiency | 87% | 89% | |||
Inrush current | Cold start current45A/115VAC 55A/230VAC | ||||
Leakage current | <1mA/240VAC | ||||
Protective properties | Overload protection | Overload protection activated at 105%~115% of rated output power | |||
Protection Mode: AC Charging Mode: Spacing Mode, Automatic Recovery after Removal of Load Abnormal Condition | |||||
Battery Low Voltage Protection | 9.5~10.3V | 19~20.5V | |||
Protection mode: cut-off output |
Functionality | UPS function introduction | Long-term on-line float charging of the battery, high charging efficiency, the battery fullness can be as high as 98% or more. | |||
Self-stopping when full, preventing overcharging and prolonging the life of the battery. | |||||
Automatic switching between mains/battery, no switching time, no need to be manned. | |||||
Cold start function, in the absence of the state of the utility, you can directly use the battery to start the UPS, to meet the emergency needs of users. | |||||
Environments | Operating temperature, humidity | -20℃~+60℃;20%~90%RH | |||
Storage temperature, humidity | -20℃~+85℃;10%~95%RH non-condensing | ||||
Seismic defences | 10~500Hz, 2G 10min./1 cycle, 60 minutes, each axis | ||||
surety | Pressure resistance | Between input and output:1.5KVAC Input and ground:1.5KVAC Output and ground:0.5KVDC | |||
Electrical insulation resistance | Between input and output: input and ground, output and ground: 100M Ohms/500VDC | ||||
Standards-compliant | Safety standard | Complies with UL60950-1 | |||
EMC standard | Conforms to EN55022, CLASS A. | ||||
Other | Size | 215*115*30mm(L*W*H) | |||
Packaging | 0.75kg/20pcs/16.5kg/0.041m³ | ||||
Note | 1. All parameters are measured at 230VAC input, rated load and 25°C unless otherwise specified. | ||||
2. Ripple and noise voltages were measured on a 20MHz bandwidth oscilloscope with a 12-inch twisted-pair cable terminated with 0.1μ and 47μ capacitors. | |||||
3. Tolerance is the sum of voltage setting error, voltage adjustment rate and current adjustment rate. |