Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency








Model | S-600-100 | S-600-110 | S-600-120 | S-600-150 | S-600-200 | S-600-220 |
DC Output voltage | 100V | 110V | 120V | 150V | 200V | 220V |
Output voltage range DC | 0-100V | 0-110V | 0-120V | 0-150V | 0-200V | 0-220V |
Rated output current | 6A | 5.4A | 5A | 4A | 3A | 2.7A |
Output current range | 0-6A | 0-5.4A | 0-5A | 0-4A | 0-3A | 0-2.7A |
Wave and noise | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
Inlet stability | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 600W | 600W | 600W | 600W | 600W | 600W |
Efficiency | 87% | 87% | 87% | 87% | 88% | 88% |
AC input voltage range | 100-132VAC/190-240VAC selected by switch 47-63Hz | |||||
Input current | 5A/230V | |||||
Setup rise hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | Input and output intemal:1.5KVAC,input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||
lsolation resistance | Input and output interal:lnput and enclosure,Output and encosure:500VDC/100MΩ | |||||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||||
Protection | Over-voltage, over-load, over-current, over-temperature | |||||
Overall dimension | 215*115*50mm(L*W*H) | |||||
Weight | 0.9kgs | |||||
Safety standards | GB4949,UL60950,EN60950 | |||||
EMC standards | According to GB9254 EN55022 EN55024 A level design | |||||||
Note: | ||||||||
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. | ||||||||
2.Error.include the setting error,line stability and load stability.(Note:5). | ||||||||
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | ||||||||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||||||
5.Load stability test:the load is from 0% to 100%. | ||||||||
6.C2,3,6must be knocked down. | ||||||||