Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-36 |
Dc output voltage | 5V | 12V | 15V | 24V | 36V |
Rated output current | 7A | 3A | 2.4A | 1.5A | 1A |
Output current rage | 0~7A | 0~3A | 0~2.4A | 0~1.5A | 0~1A |
Rated Power | 35W | 36W | 36W | 36W | 36W |
Wave and noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
Voltage ADJ. range | 4.5-5.5V | 10.2-13.8V | 13.5-18V | 21.6-28.8V | 32.4-39.6V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 82% | 86% | 86% | 88% | 88% |
AC input voltage range | AC85~264V 47~63Hz;120~373VDC | ||||
Input current | 0.7A/115V 0.42A/230V | ||||
AC INnrush current | Cold-start 45A/230V | ||||
Overload proctection | 110%~150% Potection type: Hiccp mode,recobers | ||||
automatically after condition is recoverd | |||||
Over-voltage protection | 5.75-6.9V | 13.8-16.2V | 18.75-21.75V | 28.8-33.6V | 41.4-48.6V |
Potection type :Shut down o/p voltage,re-power on to recover | |||||
Setup rise time | 1000ms,30ms/230VAC 2000ms,30ms/115VAC at full lod | ||||
Hold up time | 30ms/230VAC ,12ms/115VAC at full lod |
Withstand voltage | I/P-O/P:3.0KVAC,I/P-FG:2KVAC,O/P-FG: 1.25KVAC | ||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/ 500VDC /25°C/70%RH | ||||
Working temperature | -20°C~+70°C | ||||
Overall dimension | 99*82*30mm | ||||
Safety standards | Meet ULGB4943 UL60950 EN60950 | ||||
EMC standards | Meet EN55022,EN61000-3-2,EN61000-3-3,EN55024 GB9254 Class B | ||||
Weight | 0.23Kgs |